These are 48 frame Executive 48 frame side discharge pumps, the options have 2 inch (inlet) x 2 inch (outlet).
This European spec. motor (EMG) is recommended by Waterway for the European market, It has a rear fan and a finned body design to dissipate heat.
There are both 1 and 2 speeds available, the wet end is Part number 310-1930 and is supplied with a 4hp, industry standard impellor.



The pumps are supplied without a cable, as the power cord is dedicated to your model of control system, therefore you will need to rewire your existing cable to the pump. Remove the cord from your old pump, and note, the wire colour going to high speed or low speed terminals on any motor, the colour is set or determined by the maker of the spa control, not by the pump or motor manufacturer.
Before you remove the power cord from your old pump, look at the old motor wiring label and make a note of what color goes to high, and to low. Then, put the cord on your new motor/pump, using the same color for high as on the old motor and also for low speed wiring.
This European spec. motor (EMG) is recommended by Waterway for the European market, It has a rear fan and a finned body design to dissipate heat.
There are both 1 and 2 speeds available, the wet end is Part number 310-1930 and is supplied with a 4hp, industry standard impellor.

| 1 Speed | 2 Speed | |
| Length: | 390 mm | 390 mm |
| Height: | 200 mm | 235 mm |
| Width: | 205 mm | 205 mm |

| 2HP - Single Speed | 2HP - Two Speed | |||
| Amps: | 6 | 2.2 (low) / 6.8 (high) | ||
| Volts: | 230 | 230 | ||
| Hz: | 50 | 50 | ||
| Motor KW: | 1.4 | 0.44 (low) / 1.48 (high) | ||
| HP: | 1.5 | 0.63 (low) / 2.11 (high) | ||
| Impellor: | 1.5hp (310-0800) | 1.5hp (310-0800) | ||
| RPM: | 2820 | 1440 (low) / 2850 (high) | ||
| Capacitor: | 25uf | 16uf (low) / 30uf (high) | ||
| Fittings: | 2" x 2" inch | 2" x 2" inch |

The pumps are supplied without a cable, as the power cord is dedicated to your model of control system, therefore you will need to rewire your existing cable to the pump. Remove the cord from your old pump, and note, the wire colour going to high speed or low speed terminals on any motor, the colour is set or determined by the maker of the spa control, not by the pump or motor manufacturer.